Rise and fall with every breath. The simplest patient monitor in the room.

Model 2200B
Every small animal case. One machine.
A complete, portable cart-based anesthesia and ventilation system for small animal surgery. Available in a certified MRI-compatible version, with no electronics at all.
The all-in-one system FOR SMALL PRACTICES
Take on any small animal surgery in-house. One cart, every case - built to last decades. MRI-compatible version available.
Ascending bellows
Real knobs, clear LCD
Microprocessor precision with
dedicated physical controls. Set it, and it holds steady(only for the electronic version).
dedicated physical controls. Set it, and it holds steady(only for the electronic version).
Only for the electric version.

MRI-compatible
An optional all-pneumatic version goes inside the scanner — no electronics, no ferrous metal.
Rolls anywhere
Move the cart freely between prep, OR and imaging. Lock into place.
Ascending bellows
Rise and fall with every breath. The simplest patient monitor in the room.
Real knobs, clear LCD
Microprocessor precision with
dedicated physical controls. Set it, and it holds steady.
dedicated physical controls. Set it, and it holds steady.
Optional MRI-conditional models
Built to work inside the MRI.
Fully pneumatic. Zero electronics.
Non-ferrous throughout.
Tested at 3 Tesla.
Most anesthesia machines stop at the door of the MRI suite. Every Mallard comes in a fully pneumatic version with no electronics and no ferrous metal. It goes right into the room, stays close to your patient, and breathes for them through the entire scan. Tested at 3 Tesla.


VENTILATION, BUILT IN
The breath is already on the cart.
Includes a built-in 2400V ventilator, on the same circuit - ready the moment a patient needs a breath.
Visible ascending bellows. The same ascending design trusted in human anesthesia - proven over decades.
Catch a leak by eye. When the circuit leaks, the bellows fail to refill and visibly collapse so you catch trouble immediately.
Less work for the lungs. Engineered to lower breathing resistance, the ascending design lets every breath
come easier, even on the weakest lungs.
come easier, even on the weakest lungs.
Medical Air Add-on. Drive the ventilator with clean, purified Medical Air — a controlled alternative to pure oxygen for longer cases and more sensitive patients.
Precision control
Real knobs,
not a touchscreen.
Engineered for unparalleled reliability and ease of use, boasting a microprocessor-based control system and adjustable flow rate up to 120 Liters per minute.

Manual Inspiration Button
Flow Rate Gauge
Robust LCD display
Physical knobs
.avif)
Manual Inspiration Button
Flow Rate Gauge
Time display
Physical knobs
Engineered for durability
A Mallard from the '90s is still working today.
Built from powder-coated steel and industrial-grade bellows, the 2200B is made to run 20 years and more. In production since 1985 and named the standard of care in Lumb & Jones, it's the machine a generation of veterinarians learned on.
.avif)
+1 million
ventillated over a million patients
40+
years (since 1985)

+1 million
ventillated over a million patients
40+
years (since 1985)
Engineered in California
Four decades of craft in every machine. The standard taught in every major vet school.
World-class customer service
Free technical help for as long as you own it, direct from the people who built it - one call, and you're running again.
Built for decades
Powder-coated steel and aerospace-grade polymer, engineered from the ground up for decades of service.
Control and safety
Three safeguards.
Each works on its own.
Pneumatic, mechanical and electronic protection. So a single failure never stops the breath.
A breath without power.
Press the pneumatic button and a breath flows straight from the oxygen or air supply - no electronics needed.
Pressure held in check.
An adjustable governor starts releasing at 50 cm H₂O and fully opens by 80 - bleeding off pressure before it can ever reach the lungs.
Alarms that speak up.
Visual and audible alerts the moment anything shifts - a missed cycle, low gas, a loss of power (only for electric version)(only for electronic version).
Only for the electric version.
PRECISION VENTILATION
Quiet enough to think over, strong enough to count on.
Extremely quite & smooth in operation
The Mallards are some of the quietest anesthesia ventilator on the market - tested at just 61 dB on the small animal system and 66 dB on the large animal system, about the level of a normal conversation. The quiet, smooth operation reduces stress in the surgical environment, so your team can communicate clearly and focus on the patient, not the machine.
Rolls to the patient. Locks for the procedure.
On its portable chassis with locking casters, the Mallards moves easily between prep, surgery, and imaging - then locks firmly in place for the duration of the procedure. When the patient can't come to you, from an equine recovery stall to a zoo holding area, the machine goes where it's needed.
No disassembly required for cleaning
The bellows clean in place - no teardown, no removed parts, no service visit. Routine cleaning and maintenance can be handled in-facility by your own qualified techs, which means less downtime and a machine that stays in service, procedure after procedure.
.avif)
PRECISION VENTILATION
Quiet enough to think over, strong enough to count on.

Extremely quite & smooth in operation
The Mallard 2800C is the quietest anesthesia ventilator on the market. The quiet, smooth operation reduces stress in the surgical environment
Visible bellows
Every Mallard comes in a fully pneumatic version with no electronics and no ferrous metal.
A legacy of durability
For an equine hospital or teaching program, this is a once-in-a-career purchase
A name vets trust
The most trusted name in veterinary anesthesia.
The premium alternatives hide the bellows in a housing and bury the controls in atouchscreen. Mallard does the opposite — and has, since before software ran theoperating room.
40+ years
building ventilators since 1985
1,000,000
animals ventilated on a Mallard
2000+
units in the field
One protocol. OR to MRI.
Smart simplicity. Thoughtful design.

Classification
A microprocessor based, electronic, time cycled, pressure limited, anesthesia ventilator (MRI Upon Request)
Alarms and Alerts
* Only for the electric version
Failure to Cycle - Visual Audible Alarm
Low Gas Pressure Failure - Visual Audible Alarm
Power Failure - Visual Audible Alarm
Failure to Cycle - Visual Audible Alarm
Low Gas Pressure Failure - Visual Audible Alarm
Power Failure - Visual Audible Alarm
Controls
Pediatric Bellows Optional 50 - 300ml
Expanded Bellows - 200 - 3,000ml
Expanded Bellows - 200 - 3,000ml
Options
Medical air option
Inspiratory Time - .1 to .3 seconds
Inspiratory Flow - 1 - 120 LPM
Inspiratory Pressure Rate - 10 - 80cm H20
Inspiratory Time - .1 to .3 seconds
Inspiratory Flow - 1 - 120 LPM
Inspiratory Pressure Rate - 10 - 80cm H20
Bellows Orientation
Inverted (Ascending)
Absorber Volume For Soda Lime
2.5 Liter
Volume
Selectable - 200 - 2,200ml
Safety System
Overpressure Governor 80cm H20 (adjustable)
LCD Display
* Only for the electric version
Inspiratory Time Rate (BPM) I:E Ratio
Inspiratory Time Rate (BPM) I:E Ratio
Gas Scavenger
19mm port
How to order
Custom-built.
White-glove delivered.
01.
Configured to your practice
Tell us your caseload. We spec the right machine and options for the work you do.
02.
Hand-built to order
Assembled and tested by hand in Redding. Built for you, one at a time.
03.
White-glove delivery
Delivered with care, anywhere. Backed by a warranty and lifetime support.
Get your custom quote in 24 hours
1 million patients ventilated
Taught at 25 top U.S. vet schools, 22 worldwide
Tested 4+ hrs per unit, built for 20+ years
Trusted & supported in 37 countries
“At UC Davis, Mallard is our preferred supplier and primary choice for anesthesia equipment.“

Have a question?
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Compare our devices.
Mallard 2800CThe large-animal ventilator built to never stop working. ![]() | Mallard 2800CPOne machine, every patient. ![]() | Model 2200BEvery small animal case. One machine. ![]() | Mallard 2400VSmall animal ventilation ![]() | |
|---|---|---|---|---|
| Specifications | ||||
| Classification | A microprocessor based, electronic, time cycled, pressure limited, anesthesia ventilator | A microprocessor based, electronic, time cycled, pressure limited, anesthesia ventilator | A microprocessor based, electronic, time cycled, pressure limited, anesthesia ventilator | A microprocessor based, electronic, time cycled, pressure limited, anesthesia ventilator |
| Bellows Volume | 18L | 18 L, 2.2 L, or optional 3 L or 0-300 ml bellow | 2.2 L, optional 3 L or 0-300ml | 2.2 L, optional 3 L or 0-300ml |
| MRI compatible | Optional | Optional | Optional | Optional |
| Alarms and Alerts | ||||
| LCD Display | ||||
| Safety System | ||||
| Pneumatic Manual Push Button | ||||
| Gas Scavenger | 19mm port | 19mm port | 19mm port | 19mm port |
| Absorber Volume For Soda Lime | 6 L | 6 L | 2.5 L | |
| Bellows Orientation | Inverted (Ascending) | Inverted (Ascending) | Inverted (Ascending) | Ascending |
| Size | 37” (94cm) Width 28” (71 cm) Depth 57” (145cm) Height | 37” (94cm) Width 28” (71 cm) Depth 57” (145cm) Height | 30” ( 76 cm) Width 30” (76 cm) Depth 41-61” (114-155 cm) Height | 12” ( 30 cm) Width 11” (28 cm) Depth 16” (41 cm) Height |
| Weight | 130 lbs (59 kg) | 130 lbs (59 kg) | 50 lbs (23 kg) | 10 lbs (4.5 kg) |
| Controls | Inspiratory Time - .1 to 3 seconds Inspiratory Flow - 10 - 200 LPM Inspiratory Pressure Rate - 10 - 80cm H20 | Inspiratory Time - .1 to 3 seconds Inspiratory Flow - 1 - 200 LPM Inspiratory Pressure Rate - 10 - 80cm H20 | Inspiratory Time - .1 to .3 seconds Inspiratory Flow - 1 - 120 LPM Inspiratory Pressure Rate - 10 - 80cm H20 | Inspiratory Time - .1 to .3 seconds Inspiratory Flow - 1 - 120 LPM Inspiratory Pressure Rate - 10 - 80cm H20 |
| Options | Medical Air Option Optional Vaporizer and Mounts Available in MRI Conditional Model | Medical Air Option Optional Vaporizer and Mounts Available in MRI Conditional Model Expanded Bellows - 200 - 3,000ml Pediatric Bellow Optional 50-300ml bellow | Available in MRI Conditional Model Pediatric Bellows Optional 50 - 300ml Expanded Bellows - 200 - 3,000ml Medical Air Option Optional Vaporizer and Mounts | Available in MRI Conditional Model Pediatric Bellows Optional 50 - 300ml Expanded Bellows - 200 - 3,000ml |
Mallard 2800CThe large-animal ventilator built to never stop working. ![]() | Mallard 2800CPOne machine, every patient. Even in the MRI. ![]() | Model 2200BEvery small animal case. One machine. ![]() | Mallard 2400VSmall animal ventilation you can take into the MRI. ![]() | |
|---|---|---|---|---|
| Specifications | ||||
| Classification | Pneumatic time cycled, pressure limited, anesthesia ventilator | Pneumatic time cycled, pressure limited, anesthesia ventilator | Pneumatic time cycled, pressure limited, anesthesia ventilator | Pneumatic time cycled, pressure limited, anesthesia ventilator |
| Bellows Volume | 18L | 18 L, 2.2 L, or optional 3 L or 0-300 ml bellow | Selectable - 200 - 2,200ml | Selectable - 200 - 2,200ml |
| MRI compatible | ||||
| Alarms and Alerts | ||||
| LCD Display | Timer Display | Timer Display | Timer Display | Timer Display |
| Safety System | ||||
| Pneumatic Manual Push Button | ||||
| Gas Scavenger | 19mm port | 19mm port | 19mm port | 19mm port |
| Absorber Volume For Soda Lime | 6 L | 6 L | 2.5 L | |
| Bellows Orientation | Inverted (Ascending) | Inverted (Ascending) | Inverted (Ascending) | Ascending |
| Size | 37” (94cm) Width 28” (71 cm) Depth 57” (145cm) Height | 37” (94cm) Width 28” (71 cm) Depth 57” (145cm) Height | 30” ( 76 cm) Width 30” (76 cm) Depth 41-61” (114-155 cm) Height | 12” ( 30 cm) Width 11” (28 cm) Depth 16” (41 cm) Height |
| Weight | 130 lbs (59 kg) | 130 lbs (59 kg) | 50 lbs (23 kg) | 10 lbs (4.5 kg) |
| Controls | Inspiratory Time - .1 to 3 seconds Inspiratory Flow - 10 - 200 LPM Inspiratory Pressure Rate - 10 - 80cm H20 | Inspiratory Time - .1 to 3 seconds Inspiratory Flow - 1 - 200 LPM Inspiratory Pressure Rate - 10 - 80cm H20 | Inspiratory Time - .1 to .3 seconds Inspiratory Flow - 1 - 120 LPM Inspiratory Pressure Rate - 10 - 80cm H20 | Inspiratory Time - .1 to .3 seconds Inspiratory Flow - 1 - 120 LPM Inspiratory Pressure Rate - 10 - 80cm H20 |
| Options | Medical Air Option Optional Vaporizer and Mounts Available in MRI Conditional Model | Medical Air Option Optional Vaporizer and Mounts Available in MRI Conditional Model Expanded Bellows - 200 - 3,000ml Pediatric Bellow Optional 50-300ml bellow | Available in MRI Conditional Model Pediatric Bellows Optional 50 - 300ml Expanded Bellows - 200 - 3,000ml Medical Air Option Optional Vaporizer and Mounts | Available in MRI Conditional Model Pediatric Bellows Optional 50 - 300ml Expanded Bellows - 200 - 3,000ml |